Posted on

Containerized Mobile Incinerator Model CA50

Waste Incinerator

(Containerized Mobile Burner)


Ability: Average 50 kgs per hr

Design

CA50

Interior Dimensions

100 x 80 x 70 cm

Main Item List

Main Burning Chamber

Additional Burning Chamber

Smoke Filter Chamber

Burner Control Situation

Chimney:5.0 Meters

*( upgrade to Stainless-steel, cost-free price)

Italy oil/gas heater: 02 Components

Oil Container (if oil fuel): 200Liters

ISO 20′ ′ Container( Delivery with Burner)














Version

CA50

Waste Treatment

Waste Incineration Remedy

Feed Capability

Typical 100 kgs per feed

Burning Price

Ordinary 50 kgs per hr

Burning Time per Feed

Standard 2 hour

Control Setting

PLC( Programmable Logic Controller Incinerator)

Voltage

220V

Power

0.7 Kw

Gas

Diesel oil

Burner

Italy Burner

Feed Mode

Guidebook

Temperature Screen

Digital Display

Gas intake (Oil)

Average 16.6 Kgs/Hour

Internal Dimensions

100x80x70cm (Main Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Blog Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max.

166,000 Kcal/Hr.

























HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Medical Waste Incinerator Capacity Standard 100kgs per hour

Temperature Level Show & & PLC Control Instance

Main Burning Chamber

Incinerator Text

***Primary Combustion Chamber

Italy Oil/Gas Heater

***Chimney:10.0Meters

*** Second Combustion Chamber *** Smoke Filter Chamber

***Italy oil/gas burner: 02 units
***Oil Tank (if oil fuel): 200Liters

*** Burner PLC Control Instance


Items/Model

TS100( PLC)

Concept

Waste Incineration Treatment

Burn Price

Standard 100 kg/hour

Feed Ability

Average 200kg/feeding

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1200L

Inner Measurements

120x100x100cm

Added Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Power

0.7 Kw

Oil Utilization (kg/hour)

14—- 28

Gas Utilization (m3/hour)

10—- 32.2

Temperature Display

Digital Show

Temperature Protection

Yes

Oil Storage Tank

200L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Type

Stainless-steel

1st.

800 ℃—- -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Exterior Measurements

HICLOVER – Medical Environmental 

260x150x180cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Dual heat burners in Addition to double Room burner Burning ability up to 30 Kg per hour with wet scrubber

Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour
Main Product List
Primary Combustion Chamber(Main body stainless steel)
Secondary Combustion Chamber(Main body stainless steel)
Mix-Combustion Chamber
Wet Scrubber( Washing Tower)(Main body stainless steel)
Incinerator Control Case
Chimney:5.0Meters  Stainless Steel
Italy gas burner: 02 sets
Oil Tank (if oil fuel): 100Liters

Model

YD-30C

Feed Ability

Ordinary 50 kgs per feeding

Burning Price

Typical 30 kgs per hour

Burning Time per Feed

2 hours

Voltage

380V

Power

6 Kw

Fuel

Natural Gas

Heater

Italy Heater

Feed Setting

Handbook

Gas usage (Oil)

10.2-20.0 Kgs/Hour

Gas usage (Gas)

12.2-24.0 m3/Hour

Outside Measurements

170 x 140 x 190cm (text)

Interior Measurements

55 x 55 x 85cm( Main Chamber)

Waste combustion chamber

250Liters

Article Combustion Chamber

140Liters

Oil Tank Capacity

100 Litres

Door Opening

38 x 48cm

Chimney

5.0 M

Gross Weight

3300kgs

Chamber Material

Refractory Concrete

Max.

200,000 Kcal/Hr.

Operation Technical Specs

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature level

10000C -12000 C

Chamber Anti-Rate

13500C

Residency time

2.0 Sec.

Burning efficiency

> 98 percent

Waste Lower Calorific Power

Water showering cyclone air cleaner Stain less steel 304 grade sheet for water scrub chamber

3000Kcal

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Hiclover waste burner extra parts

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
Refractory cement,Ignition transformer – Secondary burner,Ignition transformer – Primary burner,Emergency push button,Temperature thermos couple with Locknut – 1600oC,Temperature thermos couple with Locknut – 1300oC,Temperature display controller – Secondary Chamber,Temperature display controller – Primary Chamber (Parameter – Digital Adjust Instrument),Burner Lighting Sensor (Photo Cell) PBT/PC
Circuit board (LM44.255C2BT) High Stage Secondary,Circuit board (LOA24.171B2BT) Primary
Fire proof flange gasket,Fire proof flange gasket
CA50-600,EB14HPM,26-48-3371T JT04,K1600,k1300,XMT – 3000,XMT – 2000 QRB1,LM44.255C2BT,LOA24.171B2BT,SN834457 8023020001,SN834451,3713798,AS47B,FO03,BTL20,SPARK35
Ignition electrode with leads(for burner BTL20/SPARK35),Solenoid(for burner BTL20/SPARK35),Burner fuel pump(for burner BTL20/SPARK35),Fuel filter(for burner BTL20/SPARK35)
Burner – Baltur,Burner – Baltur,Solenoid,Burner fuel pump
Ignition Cable,Ignition Switch -(Control Box),Photo Cell

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Containerized Mobile Burner Pre-assembled, containerized Kind

Model

CA100

Photo

Waste Therapy

Medical Waste Incineration Therapy

Feed Ability

Ordinary 100-200 kgs per feed

Burning Rate

Typical 100-120 kgs per hr

Burning Time per Feed

Standard 1-2 hr

Control Setting

PLC( Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Heater

Feed Mode

Handbook

Temperature Monitor

Digital Screen

Fuel intake (Oil)

Typical 20.4 Kgs/Hour

Interior Measurements

100x80x70cm (Main Combustion Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste burning chamber

560Liters

Blog Post Burning Chamber

280Liters

Oil Tank Capacity

200 Litres

Door Opening

70 x 50cm

Chimney

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max.

166,000 Kcal/Hr.

Procedure Technical Specs

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning effectiveness

> 98%

Waste Lower Calorific Power

HICLOVER – Medical Environmental 

3000Kcal


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Pyrolytic Dual Chamber Incinerator Small Size : Burning Price : 30-45 kg/hr ; Optimum Load Capability : 400 kg

Items/Model

TS50( PLC)

Picture

Principle

Strong Waste Incineration

Burn Price

30-45 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

560L

Inner Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Setting

Guide

Voltage

220V

Oil Intake (kg/hour)

Average 13.3

Gas Consumption (m3/hour)

***

Temperature Display

Digital Show

Temperature Level Defense

Yes

Oil Storage Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Chimney Kind

Stainless Steel

1st.

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Exterior Measurements

HICLOVER – Medical Environmental 

230x130x155cm


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Tool Dimension : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Incinerator

Items/Model

TS100( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

60-80 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1200L

Interior Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Setting

Manual

Voltage

220V

Oil Consumption (kg/hour)

Average 20.4

Gas Intake (m3/hour)

***

Temperature Monitor

Digital Current

Temperature Level Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st.

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Plus Size Burning Price : 150-200 kg/hr Solid Waste Devices Primary and Second Combustion Chamber Burner

Items/Model

TS500( PLC)

Picture

Concept

Waste Incineration Treatment

Burn Price

150-200 kg/hour

Control Placing

PLC( Programmable Logic Controller Burner)

Combustion Chamber

2700L

Interior Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Oil Intake (kg/hour)

Regular 28

Gas Usage (m3/hour)

***

Temperature Display

Digital Screen

Temperature Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st.

800 ℃– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

15000kg

Outside Measurements

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

400x210x300cm( without chimney)

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Mobile Cremation Devices

Layout

CA-200

Image

Burning Rate

Ordinary 100 kgs/hour

Key Burning Chamber

2000 Liters

Additional Burning Smokeshaft

Yes

Feed Mode

Guidebook

Voltage

220V

Power

3.0 Kw

Fuel Kind

Diesel Oil

Burner

Italy Original

Oil Usage (Diesel Oil)

Typical 53 kg/hour

Interior Dimensions

230 x 100 x 90cm (primary chamber)

Topical Dimensions

290 x 200 x 170cm (key chamber)

Temperature Monitor

Yes

Oil Container Capacity( if Petroleum fuel)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Chimney Sort

Stainless Steel

Devices Gross Weight

9000 kgs( with container)

Procedure Technical Specifications

Paimary Chamber Temperature

800 ℃–– 1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98 percent

Waste Lower Calorific Power


Mobile crematorium 
HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Posted on

Incinerator for medical facility waste Tracking

Burner for healthcare facility waste observation with the adhering to attributes:

– In high temperatures (pyrolytic burner 2 chambers with temperatures ranging from 950 º C to 1320 º C;

– Ability to harm of 400 to 600kg per hr;

– Efficient in destroying microbes;

– Drain ash;

– Drain needle as well as glass crusher;

– Patio with tap water for hand cleaning and decontamination;

– Observe the issue of environmental high quality standards, discharges fluent as well as policy on the problem of waste; mount big incinerator to one of the largest veterinary health centre in KSA so in the event you will certainly encourage us with a single system (big incinerator) and ecological with onsite training, the capacity for the unit is 2000 Kg for cattle, equines and also farm animals also suitable to all animal waste types, we need it diesel fired.
k). mono ethanolamine.
w). utilized tires.
Reduced intake high performance compact automated burning system.
2nd chamber-1000 deg.C– 1200 Deg.C

Resources Of The Wastes.
l). ETA, MEA waste.
v). solvent chemicals/paint wastes/used glass grains.
q). sludge mix liquid.
d). Dyes as well as intermediate waste.
Low running and upkeep rates.
m). Wastes after treatment of chemicals in etp plant.
Burner must have complying with requirements:.
Producing ash as well as Aeriform fumes which are treated with cyclone type damp scrubber as well as caustic scrubber to create air with contaminants in the allowed variety as well as Non dangerous ash chiefly not organic salts.

Incinerator utilities.
1st chamber-870 Deg.C – – 900 Deg.C.
t).
Thick refractory concrete liner ranked at 1600 C.
Large top opening cover for loading.
Fully automatic and also easy to operate control board.
e).
s). Semi powerful liquid chemical waste.
Wide door for ash removal.
f). Liquid ink waste/acidic deposit.
The twin stage incinerator aids to burn the waste in 2 phases, initially at a medium temperature of 870- 900 Deg C as well as the 2nd point at 1200 deg C.
u).
Advanced gas treatment system to avoid emission of hazardous gases (rubbing system).
r). Slurry/adhesive/grease/ powder finish wastes.
j). amino ethanol.
Capability: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with double chamber system).
y).
g). insecticides/herbicides/pesticides.

Incinerator utilities.
Burner should have complying with requirements:.
Metallic seal framework with ceramic insulation to stay clear of warm radiation and also control glowing temperature level.
Advanced gas treatment system to avoid emission of hazardous gases (rubbing system).
Reduced intake high performance compact automated burning system.
Low running and upkeep prices.
Fully automatic and also easy to operate control board.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to enable maximum Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless Steel Case.
Warmth recovery option