Posted on

pet incineration equipment

Minimum capacity: 500L

Provided with supporting structure

valves

Level indicator tank

funnel

Filter impurities in the mouth of the tank

 

 

Especifica??es técnicas

 

Incineradora a Diesel de 25Kg/h

 

 

Caixa

Dimens?es da caixa do incinerador.

 

Largura aprox: 900 mm

Comprimento aprox: 1000 mm

Altura aprox: 1000 mm

 

Dimens?es da chaminé

 

Altura min: 6000 mm

Diametro: 300 mm

 

Provido de duas camaras primarias e secundaria.

Volume da camara primaria: 0.25 m3

Volume da camara secundaria: 0.25 m3

 

Construído em a?o com revestimento refractário

Porta de remo??o de cinzas

Visor de chama nas duas camaras

Sondas de temperatura do tipo PTC

 

Queimadores

Potencia Térmica Max: 5100 Kcal/h, 59 Kw

Min 1700 Kcal/h, 20kw

 

Consumo aprox. 2.6 a 5.0 Kg/h

Tens?o -230V 50Hz

Ventilador 75W, Rotacao 2800 Rpm

Transformador de igni??o

Igni??o por meio eléctrodos

Controlador de queimador

Quadro controlador

Termómetro digital de camara primaria e secundaria

Regula??o de cabe?a de combust?o

Regula??o de ar

Combustível: Diesel

Posted on

clinical waste heaters providers


chemical reps to be utilized:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water treatment,
azotic (nitric) acid vapour with emphasis as much as 1.1 kg/m3;
2. neutralization approach: thermal degeneration;
C to +1200? C;
5. inlet stress and anxiety: as high as 2 bars;
6. automated control system;
7. total dimensions shall enable positioning the device on a cars and truck structure.
clinical waste heaters producers General Specs
6mm plate steel sheel building
11cm 1400 o C Refractory L iner
Temperature controlled Heaters
Added combustion Heating systems
Interlock Turn On Load Doors
Separate Ash Door
One 2nd second Home @ 1000 o C.
400 ° C Silicone Based Paint Full.
Alloy Temperature Noticing System.
Manufacturing facility wired as well as checked out.
Capacity-20 kg/ human resources.
Primary Chamber-1607 L.
Hearth Area-1:36 sq. m.
Secondly Chamber-694 L.
Main Heater (oil) -420,000 btu.
Second Heating system (oil) -900,000 btu.
secondary Combustion-1/ 6 hp.
Exhaust Stack-46cm x 6m.
Electrical Service-220/ 50.
Weight System-5.700 kg.
Dimension “D” -152 centimeters.
Tons Port Elevation- 60x 60 centimeters.
Ash Port Altitude -36 x 36 cm


Posted on

portable incinerator manufacturers

Tanque

Capacidade mínima: 500L

Provido de estrutura de suporte

Válvulas

Indicador de nível de tanque

Funil

Filtro de impurezas na boca do tanque

 

 

comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe

 

operation. The chamber and burner shall be designed to maintain a minimum combustion temperature of at least

 

930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as

 

a minimum, the direct manual removal into a dry

 

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

 

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

 

particles.

 

5.16.2 MEDICAL WASTE INCINERATORS

 

Medical waste incinerators shall be specifically designed by the manufacturer to dispose of all medical wastes. All

units shall be designed for 8 hours

 

per day of continuous operation and be rated in quantity per hour (i.e. kg/hr or lbs/hr).

 

Incinerator loading or charging of medical waste shall be batched-fed manually.

 

Primary combustion chamber shall be the stationary fixed-hearth (or kiln), multiple-chamber, retort type or larger

 

capacity rotary-hearth (or kiln) type. Burner and combustion air controls shall be fully automatic comprising of, as a

 

minimum, electronic ignition and all necessary interlocks and safety devices to provide safe operation. The

Posted on

medical waste incinerator china

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: –

·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste

·         Waste density: 125 to 350Kg/M3

·         Waste CV: 4000 KCAL/kg

·         Moisture content: 10-25%

·         Estimated ash residue: 5-10%

·         Nominal capacity: 30Kg/hour batch load

·         Secondary chamber: 0.5 second @ 850oC
·         Compact laboratory style

·         Two combustion chambers

·         Ecologically friendly

·         Up to 50kg of waste / hour

·         To be used for animals

Posted on

incinerators for sale

chamber and burner shall be designed to maintain a minimum combustion temperature of at least 760 to 870 C

 

(1400 to 1600 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

 

pit where cooled by water and removed by conveyor.

 

Secondary combustion chamber shall be a solid-walled and -floored, horizontal, refractory-lined cylinder type

 

incinerator designed to oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be

 

fully automatic comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to

 

provide safe operation. The chamber and burner shall be designed to maintain a minimum combustion temperature

 

of at least 930 to 1200 C (1700 to 2200 F) with a minimum gas residence (or dwell) time of 2.0 seconds. The ashremoval

 

system shall consist of, as a minimum, the direct manual removal into a dry collection hopper.

 

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

 

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

 

particles.

Posted on

chinese incinerator manufacturers

In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:

·        Capacity 100 kg/hr of waste containing up to 85% moisture

?      Two combustion chambers

·        Two fully automatic, oil fired, pressure jet burners

·        Panel board

·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel    Diesel Oil 8/ kerosene
Capacity (m3)    0.57
Ave Capacity    50 kg per hour
Ave time for Burnout     5 hrs
External Dimensions
Length    2000mm
Width    1100mm
Height including flue    3500mm
Door opening
Internal Dimensions
(primary chamber)
Length    1200mm
Width    620mm
Height     660mm
Operation
Min. operating temperature    9500C
Max. operating temperature    13200C
Residency time in second chamber    2.0 seconds
Weight    1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr

Fuel – Diesel oil   – 35 sec Redwood

Overall dimensions are as follows:

Width    2261mm

Length  3264mm

Chimney Diameter  –  390mm

Chimney Height      –  8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW

Posted on

crematorium manufacturers

Doors

The doors shall be hinged on the right hand side and can be easily opened and closed. All doors shall be manually

operated. Incinerator shall NOT incorporate automatic doors. All doors should be internally lined with pre-determined

thickness insulation and refractory cement.

 

Stack

The stack shall be fabricated from pre-determined thickness stainless steel plate suitably flanged for connection.

 

Combustion Air Blower

A combustion air blower shall be of steel construction type with built-in air damper regulation shall be provided. The

impeller shall be of the radial blade design and all rotating elements shall be dynamically balanced.

 

Burners

Burners fitted shall be of packaged fuel oil fired types. Primary chamber shall be fitted with an on/off type burner

while the secondary chamber shall be fitted with a high/low type burner. The burners shall each have a maximum rating

of300,000 kJ/hr.

 

Controls

A control system shall be provided to control all functions of the primary and secondary chambers including combustion

air distribution and burner control. It shall comprise of PLC, temperature controllers, timers, relays and switches to

provide automatic operation of the entire system. All switches and controls shall be mounted in an IP 55 rated control

panel.

 

Power Supply

The incinerators shall have a power supply of 240/415 volts, 50 Hz AC. All electrical works shall conform to SAA Wiring

Rules SA 3000 and be subject to PNG Power regulations.

Posted on

professional waste heater


medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais     6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1.36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service     220/50
System weight    5,700kg
Dimension “D”    152cm
Doad port height e    60x60cm
Ash port height e    36x36cm
General Specifications    6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1:36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000 btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service    220/50
System weight    5.700 kg
Dimension “D”    152cm
Doad port height and    60x60cm
Ash port height and    36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.


Posted on

hog insinerators

Finish

All equipment shall be painted with a coat of zinc rich primer and two coats of high temperature heat resistant

polyurethane type paint. All painted surfaces shall be prepared by either steel shot cleaning or sand blasting.

 

Identification and Name Plates

Identification and name plates containing the manufacturer’s name, model number, serial number, and other pertinent

information shall be securely fastened to the unit in readily visible locations.

 

Fuel Type and Tank

All burners shall be fuel oil (diesel) fired. For all incinerators fitted with fuel oil (diesel) type burners, the

bidder shall supply and install 1000 litres steel tank and all the necessary piping and fittings and initial supply of

1000 litres fuel oil. Where existing fuel is found to be still in good condition from site inspection, contractors must

use existing tanks and therefore must clearly specify in their bids of such usage. The tank shall be positioned at

least 2 meters above ground on steel frame next to the incinerator shed. Fuel delivery to incinerator burners shall be

by gravity feed. The tank should be fitted with a drain plug as standard.

  1. Post – combustion chamber:

Medical waste incinerator

Standard requirement:

The medical incinerator should meet the European standards 2000/76/EC.

Basic requirements:

1-Capacity 100kg/hr.

2-Work for 24 hours.

3-Unit should have enough combustion room consists of two combustion chambers (mounted vertically)

4- Unit should supply with control methods for air entry to the primary and secondary chambers and hence incineration

of the waste is accomplished.

5-The unit charging is done automatically and have an option to be done manually.

6-The ash removal is done automatically and have an option to be done manually

7-The unit should have a dry filtering unit.

8-The unit should be controlled from the control panel.

control panel :

Should show different tasks of operation using (PLC)

-Temperature in combustion chamber

-time of operation and combustion.

-different pressures.

-amount of air in combustion.

-efficiency indicator.

-emergency system in case of increasing pressure or temperature.

f- Time for gas passing:

Minimum time required for passing to combustion chamber for oxidizing 0.5 seconds at 800 degree Celsius .

1- design details:

A-primary combustion chamber:

Oxidize all waste to combustion residuals and temperature not less than 800 degree Celsius.

b- Secondary chamber:

Continue combusting combustion gas residuals and hanging particles using additional burner temperature not less than

1100 degree Celsius and this conditions is reached by harmonizing between temperature and time of passage to ensure

adequate oxidizing supplying enough air to ensure turbulence of gas all the time this is controlled from control panel.

Posted on

medical waste diesel incinerator


medical waste diesel heater Burning Cost:47.5–– – – 50kg/hour.
Minimum Operating Temperature level:850 o C( key combustion).
Optimum Operating Temperature level:1450 oC( Afterburner chamber).
Second Burning Capacity: Compulsory.
Thickness Insulation:20 mm High.
Refractory Casting: Minimum 65mm.
Strong refracting lining to hold up against:1500 oC.
Regular burn out time: optimum:3 humans resources.
Fuel type: Diesel.
Gas Consumption in L/hr:7.5 to 9.
Home time in additional chamber:2 sec.
Residue ash article 100kg: Max 3.8 kg.
Gizmo for safeguarding versus communicable spatter and/or cross-contamination by securely disinfecting needles, rings, and more by infrared warmth.
Electric characteristics.
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 kind.
2) Defenses versus over-voltage and over-current line problems.
3) Conformity with relevant Haitian standards as well as regulations.

Operational qualities.
4) Quick complete sanitation in around 5-7 s.
5) Completely separated quartz/ceramic tube, to give safety and security for the person (no open flame).
6) Operating temperature level around 820 ° C.
7) Placed on a steady base, as per instance listed below.